Back to top
91-80-41238431
Send SMS Send Inquiry
Large Flow Low Pressure Cyclone Filter Pump

Large Flow Low Pressure Cyclone Filter Pump

Product Details:

X

Product Description

Salient Features of Large Flow All in one Low Pressure Coolant Pump:

  • Pump: Impeller
  • Motor: 1500~3700 W/AC
  • Flow rate: 150~300 /min
  • Total pump head: 40~65 m

Model Numbering System

Motor capacity

1500 : 1.5kW

3700 : 3.7kW

Motor type

AC : AC 200/200/220/230 V 50/60/60/60 Hz
3 phase electric induction motor (IE3) with CE marking

I155・I305 is not applicable to 60Hz

Flow rate

50Hz

I155 : Impeller pump (5 stages/150l)

60Hz

I152 : Impeller pump (2 stages/150l)

50Hz

I305 : Impeller pump (5 stages/300l)

60Hz

I302 : Impeller pump (2 stages/300l)

Filtering method

C : cyclone type

Specification :

Item Model

Motor capacity (kW)

Flow Rate (& / min)

Total pum head (m)

Approximate weight

YTH1500AC-I155C (50Hz)

1.5

150

55

43

YTH1500AC-I152C (60Hz)

40

YTH3700AC-I305C (50Hz)

3.7

300

55

70

YTH3700AC-I302C (60Hz)

40

69

Large flow All-in-one Low-pressure coolant pump

This is a YTH corresponding to large flow & low pressure with cyclone filter. YTH-CI enables users to be free from troubles and filter maintenance around a coolant tank due to automatic clean-up unit by cyclone filter.

  • Total pump head 40~65 m
  • Maximum flow rate :
    • CI 15 x C 150 l /min
    • CI 30 x C 300 l /min
  • No suction filter is required (continuous operation only)
  • Applications to various types of coolant tanks

Plan-A Application to coolant tank + isolated clean tank

YTH-CI transfers filtered coolant from a coolant tank to an isolated clean tank. Filtered coolant is supplied to machining centers by High-Medium pressure coolant supply pumps. Chips and contaminants are pushed out from YTH-CI and collected by magnet separator or sedimentation tank.

Plan-B Application to integrated coolant tank and clean tank

YTH-CI can totally clean up a coolant tank by circulation flow. At the same time, YTH-CI also automatically backwash plate strainers between a coolant tank and a clean tank by suction of dirty coolant, which reduces maintenance work for backwash plate dramatically.

Plan-C Application to single coolant tank (without clean tank)

YTH-CI supplies filtered coolant to nozzles in a machinery tool. When the machinery tool stops metal cutting operation, YTH-CI automatically switches to cleaning of a coolant tank by circulation flow.

YTH-CI - the All in one coolant unit

  • Coolant supply Filtered coolant is supplied to avoid clogging and damages to surface of work piece
  • Chips and contaminants collection Chips and contaminants in a coolant tank is automatically collected to reduce maintenance work dramatically
  • Agitation of coolant Making circulation flow in a coolant tank delays fermentation of coolant, which results in less odor around the coolant tank
Unique reversed cyclone system enables to separate clean coolant and contaminants. Contaminants are pushed up through side surface of cyclone filter by centrifugal force and discharged. Clean coolant are collected to center of cyclone filter and boosted up by multiple-stage impellor pump.

Impeller Pump

  • Multiple-stage impellers are used for YTH-CI to boost up and supply a large quantity of coolant
  • Compatible types of fluid
  • Water-soluble coolant fluid
  • Not for Water-insoluble coolant fluid, lubricant oil or fuel oil
  • Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils

Compatible types of chips :

Material

Iron

Casting

Aluminium

Copper

Compatibility

Excellent

Excellent

Good

Excellent

Please contact us for the use of High Silicon Aluminum

Filtering Performance :

Suction Strainer

3mm (Solids larger than this must be removed in the tank)

Filter

50µm: 95% (specific gravity 2.7)
100µm: 99% (specific gravity 2.7)

Series name

C SERIES CT
(Specification : Double cyclone filter + TrochoidTM pump)

C SERIES CI
(Specification: Cyclone filter + Impeller pump)

Specifications for pump proper

Pump model

T208
50Hz / 60Hz

T216
50Hz / 60Hz

I155

I152

I305

I302

Flow rate (l /min)

12.0 / 14.4

24.0 / 28.8

150 (Maximum)

300 (Maximum)

Compatible fluid

Water-soluble coolant fluid

Maximum allowable viscosity (mm2/s)
(Filtering performance)

22

2

Liquid temperature range (oC)

-5 ~ 60

Rotational speed (r/min)

1500 / 1800

3000

3600

3000

3600

Maximum pressure (MPa)

2.0

-

Total pump head (m)

-

55

40

65

45

Filter type

Cyclone x 2 stages

Cyclone x 1 stage

Filtering performance

100µm: 99.9%-50µm: 95% (Silica sand: specific gravity2.7)

Contaminant drain port flow rate (l/min)

30~40
(Pressure 0.02MPa)

20~35
(Pressure 0.02MPa)

25~40
(Pressure 0.02MPa)

45~60
(Pressure 0.02MPa)

50~70
(Pressure 0.02MPa)

Remarks

Install a plate filter of #18 or finer mesh on the suction end of the tank.

Painted color of the pump section

Flat black (Approximately Munsell N1.0)

Approximate weight (kg)

16

23

34

33

Relief valve specifications

Type

External return type

-

Relief pressure setting (MPa)

2.0 / 1.5

-

Motor specifications*1

Model No.

750A3

1500A3

1500AC

3700AC

Specifications

3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration

Output (kW)

0.75

1.5

1.5

3.7

Voltage (V)

200/200/220/230

200/200/220/230

200/200/220/230

200/200/220/230

Frequency (Hz)

50/60/60/60

50/60/60/60

50/60/60/60

50/60/60/60

Rotational speed (r/min)

1440/1730/1745/1745

1445/1740/1750/1755

2890/3460/3485/3495

2910/3490/3515/3525

Rating

S1

Current (A)

3.80/3.40/3.40/3.40

6.80/6.40/6.00/6.00

6.00/5.80/5.40/5.20

13.6/13.2/12.2/11.8

Number of phases

3

Number of poles

4P

2P

Insulation class

F

Approximate weight (kg)

18

23

20

36

Protection rating

IP55

Efficiency class

IE3

Compliance CE

0

Enter Buying Requirement Details
Email Id
Mobile number