Large Flow Low Pressure Cyclone Filter Pump
Product Details:
Product Description
Salient Features of Large Flow All in one Low Pressure Coolant Pump:
- Pump: Impeller
- Motor: 1500~3700 W/AC
- Flow rate: 150~300 /min
- Total pump head: 40~65 m
Model Numbering System
Motor capacity |
1500 : 1.5kW |
3700 : 3.7kW |
|
Motor type |
AC : AC 200/200/220/230 V 50/60/60/60 Hz |
I155ÃÂãÃÂâÂÂÃÂûI305 is not applicable to 60Hz
Flow rate |
50Hz |
I155 : Impeller pump (5 stages/150l) |
60Hz |
I152 : Impeller pump (2 stages/150l) |
|
50Hz |
I305 : Impeller pump (5 stages/300l) |
|
60Hz |
I302 : Impeller pump (2 stages/300l) |
|
Filtering method |
C : cyclone type |
Specification :
Item Model |
Motor capacity (kW) |
Flow Rate (& / min) |
Total pum head (m) |
Approximate weight |
YTH1500AC-I155C (50Hz) |
1.5 |
150 |
55 |
43 |
YTH1500AC-I152C (60Hz) |
40 |
|||
YTH3700AC-I305C (50Hz) |
3.7 |
300 |
55 |
70 |
YTH3700AC-I302C (60Hz) |
40 |
69 |
Large flow All-in-one Low-pressure coolant pump
This is a YTH corresponding to large flow & low pressure with cyclone filter. YTH-CI enables users to be free from troubles and filter maintenance around a coolant tank due to automatic clean-up unit by cyclone filter.
- Total pump head 40~65 m
- Maximum flow rate :
- CI 15 x C 150 l /min
- CI 30 x C 300 l /min
- No suction filter is required (continuous operation only)
- Applications to various types of coolant tanks
Plan-A Application to coolant tank + isolated clean tank
YTH-CI transfers filtered coolant from a coolant tank to an isolated clean tank. Filtered coolant is supplied to machining centers by High-Medium pressure coolant supply pumps. Chips and contaminants are pushed out from YTH-CI and collected by magnet separator or sedimentation tank.
Plan-B Application to integrated coolant tank and clean tank
YTH-CI can totally clean up a coolant tank by circulation flow. At the same time, YTH-CI also automatically backwash plate strainers between a coolant tank and a clean tank by suction of dirty coolant, which reduces maintenance work for backwash plate dramatically.
Plan-C Application to single coolant tank (without clean tank)
YTH-CI supplies filtered coolant to nozzles in a machinery tool. When the machinery tool stops metal cutting operation, YTH-CI automatically switches to cleaning of a coolant tank by circulation flow.
YTH-CI - the All in one coolant unit
- Coolant supply Filtered coolant is supplied to avoid clogging and damages to surface of work piece
- Chips and contaminants collection Chips and contaminants in a coolant tank is automatically collected to reduce maintenance work dramatically
- Agitation of coolant Making circulation flow in a coolant tank delays fermentation of coolant, which results in less odor around the coolant tank
Impeller Pump
- Multiple-stage impellers are used for YTH-CI to boost up and supply a large quantity of coolant
- Compatible types of fluid
- Water-soluble coolant fluid
- Not for Water-insoluble coolant fluid, lubricant oil or fuel oil
- Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils
Compatible types of chips :
Material |
Iron |
Casting |
Aluminium |
Copper |
Compatibility |
Excellent |
Excellent |
Good |
Excellent |
Please contact us for the use of High Silicon Aluminum
Filtering Performance :
Suction Strainer |
3mm (Solids larger than this must be removed in the tank) |
Filter |
50ÃÂõm: 95% (specific gravity 2.7) |
Series name |
C SERIES CT |
C SERIES CI |
||||
Specifications for pump proper |
||||||
Pump model |
T208 |
T216 |
I155 |
I152 |
I305 |
I302 |
Flow rate (l /min) |
12.0 / 14.4 |
24.0 / 28.8 |
150 (Maximum) |
300 (Maximum) |
||
Compatible fluid |
Water-soluble coolant fluid |
|||||
Maximum allowable viscosity (mm2/s) |
22 |
2 |
||||
Liquid temperature range (oC) |
-5 ~ 60 |
|||||
Rotational speed (r/min) |
1500 / 1800 |
3000 |
3600 |
3000 |
3600 |
|
Maximum pressure (MPa) |
2.0 |
- |
||||
Total pump head (m) |
- |
55 |
40 |
65 |
45 |
|
Filter type |
Cyclone x 2 stages |
Cyclone x 1 stage |
||||
Filtering performance |
100ÃÂõm: 99.9%-ÃÂÃÂ50ÃÂõm: 95% (Silica sand: specific gravity2.7) |
|||||
Contaminant drain port flow rate (l/min) |
30~40 |
20~35 |
25~40 |
45~60 |
50~70 |
|
Remarks |
Install a plate filter of #18 or finer mesh on the suction end of the tank. |
|||||
Painted color of the pump section |
Flat black (Approximately Munsell N1.0) |
|||||
Approximate weight (kg) |
16 |
23 |
34 |
|||
Relief valve specifications |
||||||
Type |
External return type |
- |
||||
Relief pressure setting (MPa) |
2.0 / 1.5 |
|||||
Motor specifications*1 |
||||||
Model No. |
750A3 |
1500A3 |
1500AC |
3700AC |
||
Specifications |
3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration |
|||||
Output (kW) |
0.75 |
1.5 |
1.5 |
3.7 |
||
Voltage (V) |
200/200/220/230 |
200/200/220/230 |
200/200/220/230 |
200/200/220/230 |
||
Frequency (Hz) |
50/60/60/60 |
50/60/60/60 |
50/60/60/60 |
50/60/60/60 |
||
Rotational speed (r/min) |
1440/1730/1745/1745 |
1445/1740/1750/1755 |
2890/3460/3485/3495 |
2910/3490/3515/3525 |
||
Rating |
S1 |
|||||
Current (A) |
3.80/3.40/3.40/3.40 |
6.80/6.40/6.00/6.00 |
6.00/5.80/5.40/5.20 |
13.6/13.2/12.2/11.8 |
||
Number of phases |
3 |
|||||
Number of poles |
4P |
2P |
||||
Insulation class |
F |
|||||
Approximate weight (kg) |
18 |
23 |
20 |
36 |
||
Protection rating |
IP55 |
|||||
Efficiency class |
IE3 |
|||||
Compliance CE |
0 |
Other Products in 'NOP Coolant Unit' category
NIPPON OIL PUMP INDIA PRIVATE LIMITED
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |