NOP Coolant Unit EP
Product Details:
Product Description
A spectrum of Nop Coolant Unit YTh1 Pumps offered by us is procured from foremost manufacturing organization in tandem with our ingenious professionals. These type of pumps are ideal to utilized for boosting up and supplying a large quantity of coolant. It is designed by expert engineers utilizing first-in-class steel metal and and heavy duty induction motor that ensure its long working life, sturdy construction, energy efficiency and less maintenance needs. One can get these Nop Coolant Unit YTh1 Pumps in multiple models and technical specifications at industry competitive rates.
- Pump: Plunger
- Motor: 2200~3700 W/AC
- Flow rate: 12~28.8 /min
- Maximum Pressure: 7.0 MPa
Model Numbering System
Motor Capacity | 2200: 2.2 kW | |
3700: 3.7 kW | ||
Motor Typed | Standard motor | A3 AC 200/200/220/230 V |
Local Motor | AE: supplied by NOP Deutschl and (Germany) | |
Flow Rate | P008: Plunger pump, 8 cc/rev | |
P010: Plunger pump, 10 cc/rev | ||
P014: Plunger pump, 14 cc/rev | ||
P016: Plunger pump, 16 cc/rev |
For further details about the local motor, please contact to our overseas branch or subsidiaries.
Refer to page 45 for the compatible model for each relief pressure setting.
Filtering method | E: Turbulence filter type |
Relief valve | VD: External return type |
Relief pressure setting*2 | 707.0 MPa |
606.0 MPa | |
353.5 MPa | |
303.0 MPa | |
Filtering performance | C : 20 µm |
Specification:
Item Model | Motor Capacity (kW) | Flow Rate (& min) 50 Hz/ 60 Hz | Maximum Pressure (MPa) 50Hz/60Hz | Approximate weight (kg) |
YTH2200A3-P008EVD*C | 2.2 | 12.0 / 14.4 | 7.0 / 7.0 | 53 |
YTH2200A3-P010EVD*C | 15.0 / 18.0 | 7.0 / 6.0 | ||
YTH2200A3-P016EVD*C | 24.0 / 28.8 | 3.5 / 3.0 | ||
YTH3700A3-P014EVD*C | 3.7 | 21.0 / 25.2 | 7.0 / 7.0 | 62 |
YTH3700A3-P016EVD*C | 24.0 / 28.8 | 7.0 / 6.0 |
Specification:
Item Model | L | H | M | D (dia) | I(o) | TB |
YTH2200A3-P008EVD*C | 753.3 | 433 | 311 | 202 | 45 | 168 |
YTH2200A3-P010EVD*C | 753.3 | 433 | 311 | 202 | 45 | 168 |
YTH2200A3-P016EVD*C | 753.3 | 433 | 311 | 202 | 45 | 168 |
YTH3700A3-P014EVD*C | 768.3 | 448 | 326 | 243 | 45 | 187 |
YTH3700A3-P016EVD*C | 768.3 | 448 | 326 | 243 | 45 | 187 |
An All-in-one, High-to-medium Pressure Coolant Pump
All components of a coolant system are consolidated into a single YTH unit. No line and suction filters are required. The use of YTH-EP reduces the required space to about 1/20th by volume of that occupied by a conventional coolant system. The saved space expands the available plant space, resulting in a higher production efficiency.
- Maximum operating pressure: 7.0 MPa
- Maximum flow rate: 28.8 liters/min
- No suction filter is required
- No line filter is required
- No clean tank is required
- No transfer pump is required on the coolant tank end
- No plumbing is required to interconnect various components
Automatic Self-cleaning Turbulence Filter
Our special Turbulence design generates turbulence. The combined action of the turbulence and centrifugal force washes away chips from the filter automatically. The result is a maintenance-free unit with a stable high pressure and large flow rate.
- Chips larger than 20 µm in size is removed (when using water-soluble coolant fluid).
High efficiency plunger pump
Compatible types of fluid
- Water-soluble coolant fluid
- Not for lubricant oil or fuel oil
- Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils
- Relief valve is built into the unit
Huge Energy Saving Effect Reduces Utility Costs
- The use of YTH-EP results in huge energy savings over the conventional centrifugal pumps. The electric power cost is greatly reduced.
- Operating cycle: total 80 seconds cycle
- Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
- Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
- The calculation is based on operation 8hours/day,
- 365days/year, and the electric power billed at 20/kWh.
Results may differ according to the conventional pump specifications and the machining conditions reference data
Compatible types of chips :
Material | Iron | Casting | Aluminium |
Compatibility | Excellent | Excellent | Excellent |
Please contact us for the use of high hardness materials or Silumin (Silicon content of 6% or more).
Filtering Performance :
Suction Strainer | 3mm (Solids larger than this must be removed in the tank |
Filter | 20 m |
Series name | E SERIES EP | E SERIES ET-ES | ||||||
Specifications for pump proper | ||||||||
Pump model | P008 | P010 | P014 | P016 | T208 | T216 | S208 | S216 |
Flow rate (l /min) | 12.0 / 14.4 | 15.0 / 18.0 | 21.0 / 25.2 | 24.0 / 28.8 | 12.0 / 14.4 | 24.0 / 28.8 | 12.0 / 14.4 | 24.0 / 28.8 |
Compatible fluid | Water-soluble coolant fluid | Water-soluble coolant fluid / Water-insoluble coolant fluid | ||||||
Maximum allowable viscosity | 15 (20µm) | 15 (20µm) , 32 (50µm) | ||||||
Liquid temperature range (oC) | -5 ~60 | |||||||
Rotational speed (r/min) | 1500 / 1800 | |||||||
Maximum pressure (MPa) | 7.0 / 7.0 | 7.0 / 6.0 | 7.0 / 7.0 | 3.5 / 3.0 (2.2 kW) | 2.0 / 2.0 | 2.0 / 2.0 | 1.5 / 1.5 | 2.0 / 2.0 |
Total pump head (m) | - | |||||||
Filter type | Wire screen filter | |||||||
Filtering performance | 20µm | 20µm / 50µm | ||||||
Contaminant drain port flow rate (l/min) | 30~40 | |||||||
Remarks | Install a plate filter of #18 or finer mesh on the suction end of the tank. | |||||||
Painted color of the pump section | Flat black (Approximately Munsell N1.0) | |||||||
Approximate weight (kg) | 20 | 16 | ||||||
Relief valve specifications | ||||||||
Type | External return type | |||||||
Relief pressure setting (MPa) | 7.0 / 7.0 | 7.0 / 6.0 | 7.0 / 7.0 | 3.5 / 3.0 (2.2 kW) | 2.0 / 1.5 | 2.0 / 1.5 | 1.5 / 1.5 | 2.0 / 1.5 |
Motor specifications1 | ||||||||
Model No. | 2200A3 | 3700A3 | 2200A3, 3700A3 | 750A3 | 1500A3 | 750A3 | 1500A3 | |
Specifications | 3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration | |||||||
Output (kW) | 2.2 | 3.7 | 2.2 ' 3.7 | 0.75 | 1.5 | 0.75 | 1.5 | |
Voltage (V) | 200/200/220/230 | 200/200/220/230 | 200/200/220/230 | 200/200/220/230 | 200/200/220/230 | 200/200/220/230 | ||
Frequency (Hz) | 50/60/60/60 | 50/60/60/60 | 50/60/60/60 | 50/60/60/60 | 50/60/60/60 | 50/60/60/60 | ||
Rotational speed (r/min) | 1460/1755/1765/1770 | 1460/1755/1765/1765 | 1460/175 /1765/1770 1460/175 /1765/1765 | 1440/1730/1745/1745 | 1445/1740/1750/1755 | 1440/1730/1745/1745 | 1445/1740/1750/1755 | |
Rating | S1 | |||||||
Current (A) | 10.6/9.40/9.20/9.20 | 15.6/14.6/13.8/13.6 | 10.6/9.40/9.20/9.20 | 3.80/3.40/3.40/3.40 | 6.80/6.40/6.00/6.00 | 3.80/3.40/3.40/3.40 | 6.80/6.40/6.00/6.00 | |
Number of phases | 3 | |||||||
Number of poles | 4P | |||||||
Insulation class | F | |||||||
Approximate weight (kg) | 33 | 42 | 33'42 | 18 | 23 | 18 | 23 | |
Protection rating | IP55 | |||||||
Efficiency class | IE3 | |||||||
Compliance CE | O |