A spectrum of Nop Coolant Unit YTh1 Pumps offered by us is procured from foremost manufacturing organization in tandem with our ingenious professionals. These type of pumps are ideal to utilized for boosting up and supplying a large quantity of coolant. It is designed by expert engineers utilizing first-in-class steel metal and and heavy duty induction motor that ensure its long working life, sturdy construction, energy efficiency and less maintenance needs. One can get these Nop Coolant Unit YTh1 Pumps in multiple models and technical specifications at industry competitive rates.

Salient Features :
  • Pump: Plunger
  • Motor: 2200~3700 W/AC
  • Flow rate: 12~28.8 /min
  • Maximum Pressure: 7.0 MPa

Model Numbering System

Motor Capacity

2200: 2.2 kW

3700: 3.7 kW

Motor Typed

Standard motor

A3 AC 200/200/220/230 V
50/60/60/60 Hz
3 phase electric induction motor(IE3) with CE marking

Local Motor

AE: supplied by NOP Deutschl and (Germany)
AF: supplied by NOP Taiwan
AJ: supplied by NOP Asia (China)
AK: supplied by NOP India

Flow Rate

P008: Plunger pump, 8 cc/rev

P010: Plunger pump, 10 cc/rev

P014: Plunger pump, 14 cc/rev

P016: Plunger pump, 16 cc/rev

For further details about the local motor, please contact to our overseas branch or subsidiaries.

Refer to page 45 for the compatible model for each relief pressure setting.

Filtering method

E: Turbulence  filter type

Relief valve

VD: External return type

Relief pressure setting*2

707.0 MPa

606.0 MPa

353.5 MPa

303.0 MPa

Filtering performance

C : 20 µm

Specification:

Item Model

Motor Capacity (kW)

Flow Rate (& min) 50 Hz/ 60 Hz

Maximum Pressure (MPa) 50Hz/60Hz

Approximate weight (kg)

YTH2200A3-P008EVD*C

2.2

12.0 / 14.4

7.0 / 7.0

53

YTH2200A3-P010EVD*C

15.0 / 18.0

7.0 / 6.0

YTH2200A3-P016EVD*C

24.0 / 28.8

3.5 / 3.0

YTH3700A3-P014EVD*C

3.7

21.0 / 25.2

7.0 / 7.0

62

YTH3700A3-P016EVD*C

24.0 / 28.8

7.0 / 6.0

Specification:

Item Model

L

H

M

D (dia)

I(o)

TB

YTH2200A3-P008EVD*C

753.3

433

311

202

45

168

YTH2200A3-P010EVD*C

753.3

433

311

202

45

168

YTH2200A3-P016EVD*C

753.3

433

311

202

45

168

YTH3700A3-P014EVD*C

768.3

448

326

243

45

187

YTH3700A3-P016EVD*C

768.3

448

326

243

45

187

An All-in-one, High-to-medium Pressure Coolant Pump

All components of a coolant system are consolidated into a single YTH unit. No line and suction filters are required. The use of YTH-EP reduces the required space to about 1/20th by volume of that occupied by a conventional coolant system. The saved space expands the available plant space, resulting in a higher production efficiency.

  • Maximum operating pressure: 7.0 MPa
  • Maximum flow rate: 28.8 liters/min
  • No suction filter is required
  • No line filter is required
  • No clean tank is required
  • No transfer pump is required on the coolant tank end
  • No plumbing is required to interconnect various components

Automatic Self-cleaning Turbulence Filter

Our special Turbulence design generates turbulence. The combined action of the turbulence and centrifugal force washes away chips from the filter automatically. The result is a maintenance-free unit with a stable high pressure and large flow rate.

  • Chips larger than 20 µm in size is removed (when using water-soluble coolant fluid).

High efficiency plunger pump

Compatible types of fluid

  • Water-soluble coolant fluid
  • Not for lubricant oil or fuel oil
  • Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils
  • Relief valve is built into the unit

Huge Energy Saving Effect Reduces Utility Costs

  • The use of YTH-EP results in huge energy savings over the conventional centrifugal pumps. The electric power cost is greatly reduced.
  • Operating cycle: total 80 seconds cycle
  • Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
  • Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
  • The calculation is based on operation 8hours/day,
  • 365days/year, and the electric power billed at 20/kWh.

Results may differ according to the conventional pump specifications and the machining conditions reference data

Compatible types of chips :

Material

Iron

Casting

Aluminium

Compatibility

Excellent

Excellent

Excellent

Please contact us for the use of high hardness materials or Silumin (Silicon content of 6% or more).

Filtering Performance :

Suction Strainer

3mm (Solids larger than this must be removed in the tank

Filter

20 m


Series name

E SERIES EP
(Specification: TurbulenceTM filter + Plunger pump)

E SERIES ET-ES
(Specification: TurbulenceTM filter + TrochoidTM pump)

Specifications for pump proper

Pump model

P008
50Hz / 60Hz

P010
50Hz / 60Hz

P014
50Hz / 60Hz

P016
50Hz / 60Hz

T208
50Hz / 60Hz

T216
50Hz / 60Hz

S208
50Hz / 60Hz

S216
50Hz / 60Hz

Flow rate (l /min)

12.0 / 14.4

15.0 / 18.0

21.0 / 25.2

24.0 / 28.8

12.0 / 14.4

24.0 / 28.8

12.0 / 14.4

24.0 / 28.8

Compatible fluid

Water-soluble coolant fluid

Water-soluble coolant fluid / Water-insoluble coolant fluid

Maximum allowable viscosity
(mm2/s)(Filtering performance)

15 (20µm)

15 (20µm) , 32 (50µm)

Liquid temperature range (oC)

-5 ~60

Rotational speed (r/min)

1500 / 1800

Maximum pressure (MPa)

7.0 / 7.0

7.0 / 6.0

7.0 / 7.0

3.5 / 3.0 (2.2 kW)
7.0 / 6.0 (3.7 kW)

2.0 / 2.0

2.0 / 2.0

1.5 / 1.5

2.0 / 2.0

Total pump head (m)

-

Filter type

Wire screen filter

Filtering performance

20µm

20µm / 50µm

Contaminant drain port flow rate (l/min)

30~40
(Pressure 0.02MPa)

Remarks

Install a plate filter of #18 or finer mesh on the suction end of the tank.

Painted color of the pump section

Flat black (Approximately Munsell N1.0)

Approximate weight (kg)

20

16

Relief valve specifications

Type

External return type

Relief pressure setting (MPa)

7.0 / 7.0

7.0 / 6.0

7.0 / 7.0

3.5 / 3.0 (2.2 kW)
7.0 / 6.0 (3.7 kW)

2.0 / 1.5

2.0 / 1.5

1.5 / 1.5

2.0 / 1.5

Motor specifications1

Model No.

2200A3

3700A3

2200A3, 3700A3

750A3

1500A3

750A3

1500A3

Specifications

3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration

Output (kW)

2.2

3.7

2.2 ' 3.7

0.75

1.5

0.75

1.5

Voltage (V)

200/200/220/230

200/200/220/230

200/200/220/230

200/200/220/230

200/200/220/230

200/200/220/230

Frequency (Hz)

50/60/60/60

50/60/60/60

50/60/60/60

50/60/60/60

50/60/60/60

50/60/60/60

Rotational speed (r/min)

1460/1755/1765/1770

1460/1755/1765/1765

1460/175 /1765/1770 1460/175 /1765/1765

1440/1730/1745/1745

1445/1740/1750/1755

1440/1730/1745/1745

1445/1740/1750/1755

Rating

S1

Current (A)

10.6/9.40/9.20/9.20

15.6/14.6/13.8/13.6

10.6/9.40/9.20/9.20
15.6/14.6/13.8/13.6

3.80/3.40/3.40/3.40

6.80/6.40/6.00/6.00

3.80/3.40/3.40/3.40

6.80/6.40/6.00/6.00

Number of phases

3

Number of poles

4P

Insulation class

F

Approximate weight (kg)

33

42

33'42

18

23

18

23

Protection rating

IP55

Efficiency class

IE3

Compliance CE